Get quotes on CPP’s entire catalog of products! When you see a product you want a price for, add it to your cart. When done, review your list and submit.
The Weight Operated Leak Detector with HD Plug is engineered to capture and manage fluid leaking past stuffing box packing, helping operators prevent spills, protect equipment, and reduce environmental risk. This system operates by monitoring the accumulated weight of fluid collected in the stainless steel reservoir. When the preset weight threshold is reached, the electrical switch automatically shuts down the pumping unit to prevent overflow and costly cleanup.
Available in explosion-proof and non-explosion-proof configurations, the leak detector features an adjustable spring mechanism that allows operators to customize the activation point based on operating conditions. Combined with APT’s HD Plug, this system delivers enhanced sealing performance, dependable leak containment, and long-lasting reliability in demanding oilfield applications.
| ELECTRICAL SPECIFICATIONS |
|---|
|
SWITCH CONFIGURATION |
| SWITCH RATING 120 VDC, 60Hz, 3A (max.) |
| CERTIFICATION Class I, Division I, Groups A,B,C,D Class II, Division I, Groups E,F,G |
| TEMPERATURE -25 to +109 Celsius |
| SWITCH MATERIAL Solid Tungsten Bar and Plate |
Ideal for: